Home > Technical documentation

Technical specifications of induction motor capacitors

Following are the diagrams “loss angle tangent vs. temperature change” and “rated capacity vs. temperature change”:

Technical specifications Property value
Capacity 2...100 mF
Rated voltage 250...500 V
Preferable capacity deviation ±5%...±10 %
Loss angle tangent < 0,005
Maximum permissible voltage between terminals 1.2 Unom
Environmental temperature conditions:
High:
а) limit 100 С
б) operating 85 С
Low:
а) limit -60 С
б) operating -40 С
Temperature change:
From low operating -40 С
To high operating 85 С
Elevated relative humidity 95 %
Insulation resistance between case and terminals 10 000 МΩ
Dielectric type polypropylene
Design version Plastic case
Protection grading P0