Technical specifications of balancing capacitors for gas-discharge lamps

НFollowing are the diagrams “loss angle tangent vs. temperature change” and “rated capacity vs. temperature change”:

Technical specifications Property value
Capacity 2…100 mF
Rated voltage 250…500V
Capacity permissible deviation ±5%…±10%
Loss angle tangent < 0.005
Maximum permissible voltage between terminals 1.2 Unom
Test voltage between terminals 1.5 Unom (2 sec)
Test voltage “terminal – case” 3 kV (2 sek)
Operating frequency range 50-60 Hz
Minimum operating temperature -40 С
Maximum operating temperature +85 С
Dielectric type Polypropylene
Design version Plastic case